Transports and services

Gare Centrale de Montréal

Establishment assessed on

Accessibility rating
Partially accessible

Establishment details

  • Interior parking lot
  • More than 201 parking spaces
  • Asphalted ground
  • Flat ground
  • Parking-permit dispenser
  • Parking-permit dispenser. Slots and control buttons too high : 1,4 m
  • One or more reserved parking spaces : 2
  • Reserved parking spaces near the entrance
  • No obstacle between parking lot and entrance
  • Narrow walkway : 100 cm
  • Walkway between parked cars

  • Passageway: larger than 92 cm

  • Access to entrance: gentle sloop
  • Clear width of door exceeds 80 cm
  • Outside door pull handle (D type)
  • Inside door pull handle (D type)
  • Hallway larger than 2.1 m x 2.1 m
  • Clear 2nd door width: 80 cm
  • 2nd door: outside door pull handle (D type)
  • 2nd door: inside door pull handle (D type)

  • Access to entrance steeply sloped : 10 %
  • Clear width of door exceeds 80 cm
  • Automatic Doors
  • Hallway larger than 2.1 m x 2.1 m
  • Clear 2nd door width: 80 cm
  • The 2nd door is automatic

  • Passageway for accessing to toilet room larger than 1,1 m
  • Sink height: between 68.5 cm and 86.5 cm
  • Clearance under the sink: larger than 68.5 cm
  • Clearance width under the sink larger than 76 cm
  • Clearance depth under the sink more than 28 cm
  • clear space area in front of the sink larger than 80 cm x 1.2 m
  • Sink: push type faucets : 10 seconds
  • 1 12
  • Accessible toilet stall: door clear width larger than 80 cm
  • Accessible toilet stall: door opening outside the stall
  • Accessible toilet stall: door opening in front of the toilet bowl
  • Accessible toilet stall: no outside door handle
  • Accessible toilet stall: inside door handle (D type)
  • Narrow accessible toilet stall : 1,5 m x 1,35 m
  • Accessible toilet stall: narrow manoeuvring space : 1,5 m x 0,75 m
  • Accessible toilet stall: narrow clear space area on the side : 75 cm
  • Accessible toilet stall: no grab bar behind the toilet
  • Accessible toilet stall: diagonal grab bar at right is on the wrong bending

  • Passageway for accessing to toilet room larger than 1,1 m
  • Entrance: toilet room door width larger than 80 cm
  • Entrance: outside door pull handle (D type)
  • Entrance: inside door pull handle (D type)
  • Sink height: between 68.5 cm and 86.5 cm
  • Inadequate clearance under the sink : 56 cm
  • Clearance width under the sink larger than 76 cm
  • Clearance depth under the sink more than 28 cm
  • clear space area in front of the sink larger than 80 cm x 1.2 m
  • Sink: push type faucets : 0 seconds
  • 1 2
  • Accessible toilet stall: narrow door clear width
  • Accessible toilet stall: door opening inside the stall
  • Accessible toilet stall: door opening in the clear space area
  • Accessible toilet stall: outside door handle (D type)
  • Accessible toilet stall: inside door handle (D type)
  • Accessible toilet stall: space larger than 1.5 m x 1.5 m : 1,5 m x 1,5 m
  • Accessible toilet stall: manoeuvring space larger tham 1.2 mx 1.2 m
  • Accessible toilet stall: more than 87.5 cm of clear space area on the side
  • Accessible toilet stall: no grab bar behind the toilet
  • Accessible toilet stall: horizontal grab bar at the left

  • Outside menu too high : 2 m
  • 50% of the tables are accessible.
  • Passageway between tables larger than 92 cm
  • Manoeuvring space diameter larger than 1.5 m available
  • Table height: between 68.5 cm and 86.5 cm
  • Inadequate clearance under the table
  • Width under the table larger than 68.5 cm
  • Inadequate depth under the table : 35 cm
  • Cash stand is too high
  • Cash counter: no clearance
  • Cash counter: passageway to longer than 92 cm
  • Cash counter: manoeuvring space larger than 1.5 m x 1.5 m
Contact details

895, rue De La Gauchetière Ouest, Montréal, Québec

514 871 8422,

Visit the website