Accommodations

Hôtel de la Rive

Establishment assessed on

Accessibility rating
Partially accessible
Good to know
  • Number of partialy accessible rooms :2
  • Number of rooms :98

Establishment details

Type of parking

  • Outside

Number of reserved places

  • Reserved seat(s) for people with disabilities: : 2

Reserved seat location

  • Near the entrance

Reserved seat size

  • Free width of at least 2.4 m
  • Free width of the side aisle on the side of at least 1.5 m

Route leading from the parking lot to the entrance

  • Accident
  • Steep slope

Front door

  • Maneuvering area on each side of the door at least 1.5 m wide x 1.5 m deep
  • Sliding doors

Elevator

  • Maneuvering space at least 1.5 m wide x 1.5 m deep located in front of the door
  • Dimension : 1,3 m wide x 1,73 m deep

Counter

  • Reception desk
  • Counter surface : 115 cm above floor
  • No clearance under the counter
  • Wireless or removable payment terminal

Additional information

    • All parts of the hotel are accessible by elevator, with the exception of the Fleuve Saint-Laurent and Yamaska reception rooms.

      Interior maneuvering space

      • Restricted Maneuvering Space : 1,4 m wide x 1,4 meters deep

      Toilet bowl

      • Transfer zone on the side of the bowl of at least 90 cm

      Grab bar(s)

      • Horizontal to the right of the bowl
      • Horizontal behind the bowl

      Washbasin

      • Accessible sink

      Interior maneuvering space

      • Restricted Maneuvering Space : 1,2 m wide x 1,2 meters deep

      Toilet bowl

      • Transfer zone on the side of the bowl : 74 cm

      Grab bar(s)

      • Horizontal to the left of the bowl
      • Horizontal behind the bowl

      Washbasin

      • Accessible sink

      Changing table

      • Accessible baby changing table

        • Path of travel exceeds 92 cm
        • ronde

          Additional information

            • Room accessible only by steps.

                • Path of travel exceeds 92 cm
                • ronde

                  Additional information

                    • Room accessible only by steps.

                        • Path of travel exceeds 92 cm
                        • ronde

                            • Path of travel exceeds 92 cm
                            • ronde

                              Lighting

                              • Direct lighting of unsuitable light intensity in the main activity areas : Corridors menant aux chambres et à l'escalier de secours

                              Signaling

                              • Signage is easy to understand (through its use of pictograms and an accessible language register)

                              Interior staircase

                              • No anti-slip strip of contrasting color on the nosing of the steps
                              • The majority of staircases have a handrail on each side

                              Elevator

                              • Symbols and characters on the landing buttons and control panel in Braille
                              • Symbols and characters on the landing buttons and control panel in relief
                              • Announcement of the floor by voice synthesis before the doors open

                              Interior lighting

                              • Insufficient lighting / shadow area on the interior route : corridors menant aux chambres et à l'escalier de secours

                              Counter and payment

                              • Touchscreen keyboard accessible to a blind or visually impaired person

                              Raised writing

                              • No transcription in relief

                              Braille transcription

                              • No Braille transcription

                              Room number

                              • No raised number
                              • No Braille transcription

                              Building Interior

                              • No audible and flashing fire system

                              Accommodation unit

                              • No visual doorbell

                              Interior entrance door

                              • Maneuvering space of at least 1.5 m x 1.5 m
                              • Free width of at least 80 cm

                              Indoor circulation

                              • Maneuvering space of at least 1.5 m in diameter
                              • Circulation corridor of at least 92 cm

                              Bed(s)

                              • Mattress Top : 63,2 cm above floor
                              • No clearance under the bed
                              • Maneuvering area on the side of the bed at least 1.5 m wide x 1.5 m deep

                              Possibility of moving the furniture at the request of the customer

                              • Furniture can be moved as needed

                              Balcony

                              • Maneuvering space in front of the door leading to the balcony of at least 1.5 m in diameter
                              • Difference in level between the interior floor covering and the door sill : 4,5 cm
                              • Level difference between balcony flooring and door sill : 13 cm

                              Bed(s)

                              • 1 bed
                              • Queen-size bed
                              • Transfer zone on side of bed exceeds 92 cm

                              Interior maneuvering area

                              • Maneuvering area : 1,15 m width x 1,15 m depth

                              Toilet bowl

                              • Transfer area on the side of the bowl at least 90 cm wide x 1.5 m deep

                              Grab bar to the left of the toilet

                              • Horizontal grab bar

                              Grab bar behind the toilet

                              • A horizontal grab bar

                              Sink

                              • Accessible sink

                              Bath

                              • Shower bath
                              • Non-slip bottom
                              • Bath bench available on request
                              • Shower phone at a height of : 1,87 m from the bottom of the bath

                              Bath: grab bar on right side wall

                              • Vertical bar

                              Bath: grab bar on the wall facing the entrance

                              • Horizontal or L-shaped bar
                              • Situated at : 52 cm above the edge of the bath

                              Description

                              Bed height (floor above mattress) room 102 : 63,2 cm/ without clearance.
                              This data was collected during our visit on april, 4th 2025.
                              For other details of the accommodation unit, please refer to the section below.
                              IMPORTANT NOTE: The convention center is partially accessible. Some rooms on the upper level have stairs.

                              Contact details

                              165, chemin Sainte-Anne, Sorel-Tracy, Québec

                              450 742 5691, 800 369 0059,

                              Visit the website