Establishment details
Front door
- Difference in level between the exterior floor covering and the door sill : 3 cm
- Free width of at least 80 cm
- Opening requiring significant physical effort
- No electric opening mechanism
Additional information
- The second door back inside has a 4 cm threshold.
Ramp
- Presence of a landing every 9 m
- The ramp is not adequately lit
- Handrail on one side only
Front door
- Steep Slope Bevel Level Difference : 9 %
- Door equipped with an electric opening mechanism
2nd Entrance Door
- Pressure plate/electric opening control button is difficult to locate : Difficilement atteignable à cause de la plante
Ramp
- Steep slope : 8,5 %
Interior entrance door
- Free width of at least 80 cm
- Opening requiring significant physical effort
- No electric opening mechanism
Additional information
- The sauna door and the shower door next to it are 70 cm wide.
- The steam bath door has a clear width of 80 cm.
Course without obstacles
- Circulation corridor without slope
- Clear width of the circulation corridor of more than 92 cm
Counter
- Counter surface : 106 cm above floor
- Clearance under counter
- Wireless or removable payment terminal
- Access to shower stall: no slope
- Shower stall: surface area exceeds 1.5 m x 1.5 m
- Shower stall: no bench
- Shower stall: no grab bar
- Roll-in shower (shower without sill)
- Shower: clear width of entrance exceeds 1 m
- Shower: no hand-held shower head
- Shower: removable transfer bench available
Additional information
- The women's shower has an open entrance with no door. The men's shower has a closing door of sufficient width.
- 100% of paths of travel accessible around swimming pool
- Near swimming pool: manoeuvring space with diameter of at least 1.5 m available
- Swimming pool: no equipment adapted for disabled persons
- Access to swimming pool : 5 steps
Additional information
- Handrails to access each spa.
- Contrasting color strip on each step.
Entrance door to the locker room
- Maneuvering area inside in front of the door : 1 m wide 1,5 x _ m depth
- When you have to push the door: no lateral clearance on the side of the handle
- Opening requiring significant physical effort
Lockers
- Locker handle height : 50 cm above the ground
- Handle difficult to use
- Lock system : 50 cm above the ground
Dressing cabin
- Accessible dressing room
- No bench
- Massage room: door difficult to open
- Massage room: clear width of door exceeds 80 cm
- Massage room: path of travel around massage table exceeds 92 cm
- Massage room: massage table adjustable
Additional information
- At its lowest point, the top of the adjustable massage table is 61 cm from the floor. In the solo room, 1.2 m of space is available between the wall and the table.
- Every other relaxation room is accessible.
Presence of slope
- Gentle slope
Number of reserved places
- Reserved seat(s) for people with disabilities: : 2
Charging station for electric vehicles
- Located on a concrete base and without a curb
- Parking Space Clear Width, Restricted : 2,8 m
- Gun and/or elevated controls : 1,5 m
Route leading from the parking lot to the entrance
- Without obstacles
Additional information
- No sign to indicate the second parking space.
Door
- Interior Maneuvering Space : 1,1 m wide x 1,5 m depth in front of the door / baffle type door
- Free width of at least 80 cm
- Opening requiring significant physical effort
Washbasin
- Raised surface : 91 cm above floor
Urinal
- Not equipped for disabled people
Accessible washroom(s)
- Indoor maneuvering space at least 1.2 m wide x 1.2 m deep inside
Accessible washroom bowl
- Transfer zone on the side of the toilet bowl of at least 90 cm
- No back support for tankless toilet
Accessible toilet stall grab bar(s)
- Horizontal to the right of the bowl
- Horizontal behind the bowl
Other components of the accessible toilet cubicle
- Toilet Paper Dispenser : 50 cm above the floor
Signaling
- Accessible toilet room: no signage
Door
- Interior Maneuvering Space : 1,1 m wide x 1,5 m depth in front of the door / baffle type door
- Free width of at least 80 cm
- Opening requiring significant physical effort
Washbasin
- Raised surface : 91 cm above floor
Accessible washroom(s)
- Indoor maneuvering space at least 1.2 m wide x 1.2 m deep inside
Accessible washroom bowl
- Transfer zone on the side of the toilet bowl of at least 90 cm
- No back support for tankless toilet
Accessible toilet stall grab bar(s)
- Horizontal to the right of the bowl
- Horizontal behind the bowl
Other components of the accessible toilet cubicle
- Toilet Paper Dispenser : 50 cm above the floor
Signaling
- Accessible toilet room: no signage
Description
The baths on the rear terrace are not accessible to wheelchair users.
The treatment center (massage therapy and steam baths) is partially accessible.
Contact details
50, rue de la Ferme, Baie-Saint-Paul, Québec
418 240 4100, reservations.legermaincharlevoix@germainhotels.com
Visit the website